185.00x150.00x86.00 (mm) 7.28x5.91x3.39 (inch) |
| |
VOLTAGE: DC-36V ~ -72V INPUT CURRENT: 12.0A(RMS). FOR -48 VDC INRUSH CURRENT: 20A MAX |
| | | |
|
Output Voltage |
Output Current Min. |
Output Current Max. |
Output Current Peak |
Regulation Load |
Regulation Line |
Output Ripple & Noise Max.[P-P] |
+5V |
3.0 |
32.00 |
|
± 5% |
± 1% |
50mV | | |
|
-5V |
0.1 |
0.5 |
|
± 6% |
± 1% |
120mV | | |
|
+12V |
2.5 |
25 |
|
+7 / -5 % |
± 1% |
120mV | | |
|
-12V |
0.1 |
1.2 |
|
± 10% |
± 1% |
150mV | | |
|
+3.3V |
1.0 |
25 |
|
± 5% |
± 1% |
50mV | | |
|
+5VSB |
0.1 |
2 |
|
± 5% |
± 1% |
50mV | | |
|
|
|
|
|
|
|
|
* TEMPERATURE RANGE : OPERATING 100C --- 400C * HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95% * REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS * HOLD UP TIME: 1.6 ms MINIMUM AT FULL LOAD & NOMINAL INPUT VOLTAGE * DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 SECOND INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND * EFFICIENCY: 65% TYPICAL, AT FULL LOAD * POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms * OVER LOAD PROTECTION: 130 ± 20%. * OVER VOLTAGE PROTECTION: +5V → 5.5V ~ 7.0V, + 3.3V → 4.0V ~ 4.5V . SHORT CIRCUIT:5V,12V,3.3V * EMI NOISE FILTER: FCC CLASS A, CISPR22 CLASS A * SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950 * REMOTE ON / OFF CONTROL THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE / ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STANDBY), AS LOGIC LEVEL IS LOW, OUTPUTS VOLTAGE WERE ENABLE, AS LOGIC LEVEL IS HIGH, OUTPUTS VOLTAGE WERE DISABED * COOLING : TWO 40 mm DC FANS (MODULE) * AC INLET IN EACH MODULE
| | | | |