产品信息
    伊顿断路器LD3600F STYLE:6613C98G22
    价格:6 元(人民币) 产地:进口
    最少起订量: 发货地:厦门
    上架时间:2017/8/24 浏览量:233
    厦门纪扬科技有限公司
    经营模式:商业服务 公司类型:私营合伙企业
    所属行业:柱塞马达 主要客户:机械工业

    联系方式

    联系人:李经理 (先生)

    手机:19996826231

    电话:0592-19996826231

    传真:0592-5901026

    邮箱:624232572@qq.com

    地址:厦门市翔安区鼓岩路1号华论国际1003室

    详情介绍

    54-44-90 O2 Oxygen
    54-44-01 CO Carbon Monoxide
    54-44-02 H2S Hydrogen Sulfide
    54-44-03 SO2 Sulfur Dioxide
    54-52-01 CO Carbon Monoxide
    54-52-02 H2S Hydrogen Sulfide
    54-45-90 O2 Oxygen
    54-45-01 CO Carbon Monoxide  
    54-45-05 CO+ CO Plus  
    54-45-19 CO-H CO Minus  
    54-45-02 H2S Hydrogen Sulfide  
    54-45-03 SO2 Sulfur Dioxide  
    54-45-21 NH3 Ammonia  
    54-45-18 Cl2 Chlorine (specific)  
    54-45-09 NO2 Nitrogen Dioxide  
    54-45-10 HCN Hydrogen Cyanide  
    54-45-13 PH3 Phosphine  
    54-47-90 O2 Oxygen (2 years) 0 – 30%/Vol. 0.1%
    54-47-01 CO Carbon Monoxide 0 – 1000 PPM 1 PPM
    54-47-05 CO+ CO Plus dual purpose CO: 0 – 1000 PPM 1 PPM
    CO/H2S (provides a H2S: 0 – 200 PPM 1 PPM
    non-specific readout
    for CO and H2S)
    54-47-19 CO-H CO Minus, reduced 0 – 1000 PPM 1 PPM
    sensitivity to H2
    54-47-02 H2S Hydrogen Sulfide 0 – 200 PPM 1 PPM
    54-47-03 SO2 Sulfur Dioxide 0 – 20 PPM 0.1 PPM
    54-47-21 NH3 Ammonia 0 – 100 PPM 1 PPM
    54-47-18 Cl2 Chlorine (specific) 0 – 20 PPM 0.1 PPM
    54-47-09 NO2 Nitrogen Dioxide 0 – 20 PPM 0.1 PPM
    54-47-10 HCN Hydrogen Cyanide 0 – 100 PPM 0.1 PPM
    54-47-13 PH3 Phosphine 0 – 20 PPM 0.01 PPM
    54-47-03 SO2 Sulfur Dioxide 0 – 100 PPM 0.1 PPM
    54-46-101 Replacement sensor filter.
    35-964 Lanyard for ToxiLtd and
    ToxiPro.
    54-46-102 Replacement belt clip for
    ToxiLtd and ToxiPro.
    54-46-103 Replacement clothes clip for
    ToxiLtd and ToxiPro.
    54-46-109 Replacement cell phone-style
    swivel clip.
    54-46-104 Manual sample draw kit.
    Includes adapter, probe, and 10'
    tubing. Not for use with Cl2.
    54-46-105 Case for Value Pack. Foam-lined
    case, with room for 1 compact
    sized calibration gas cylinder.
    54-46-106 Calibration/sample draw
    adapter.
    54-46-107 Calibration adapter. Includes
    FEP lined tubing for reactive
    gases (NH3, Cl2, HCN and
    NO2).
    54-46-108 ToxiPro datalogger upgrade.
    Field upgradeable.
    54-26-0603 ToxiPro BioTrak Software Kit.
    Includes BioTrak software and
    manual.
    54-37-90 O2 Oxygen
    54-37-01 CO Carbon Monoxide  
    54-37-05 CO+ “CO Plus”  
    54-37-19 CO-H CO Minus, reduced sensitivity to H2  
    54-37-02 H2S Hydrogen Sulfide  
    54-37-03 SO2 Sulfur Dioxide  
    54-37-21 NH3 Ammonia  
    54-37-08 Cl2 Chlorine (non-specific)  
    54-37-18 Cl2 Chlorine (specific)  
    54-37-09 NO2 Nitrogen Dioxide  
    54-37-10 HCN Hydrogen Cyanide  
    54-37-13 PH3 Phosphine  
    54-37-80A LEL LEL (Alkaline)  
    54-37-80ND   LEL LEL (Rechargeable)  
    54-39-90 O2 Oxygen (2 years) 0 – 30%/Vol. 0.1%
    54-39-01 CO Carbon Monoxide 0 – 1000 PPM 1 PPM
    54-39-05 CO+ Dual purpose CO/H2S CO: 0 – 1000 PPM 1 PPM
    Provides a non-specific H2S: 0 – 200 PPM 1 PPM
    readout for CO and H2S
    54-39-19 CO-H CO Minus, reduced sensitivity 0 – 1000 PPM 1 PPM
    to H2
    54-39-02 H2S Hydrogen Sulfide 0 – 200 PPM 1 PPM
    54-39-03 SO2 Sulfur Dioxide 0 – 100 PPM 0.1 PPM
    54-39-21 NH3 Ammonia 0 – 100 PPM 1 PPM
    54-39-08 Cl2 Chlorine (non-specific) 0 – 20 PPM 0.1 PPM
    54-39-18 Cl2 Chlorine (specific) 0 – 20 PPM 0.1 PPM
    54-39-09 NO2 Nitrogen Dioxide sensor 0 – 20 PPM 0.1 PPM
    54-39-10 HCN Hydrogen Cyanide 0 – 100 PPM 0.1 PPM
    54-39-13 PH3 Phosphine 0 – 10 PPM 0.01 PPM
    54-38-03 Rubber boot.
    54-38-04 Toxi Vision PC programming
    kit. Includes software and
    serial interface cable.
    35-964 Lanyard for Toxi Vision.
    54-38-05 Replacement belt clip.
    54-38-06 Manual sample draw kit.
    Includes adapter, probe, and
    10  tubing Not for use with
    Cl2.
    54-38-07 Case for Value Pack. Foamlined
    case, with room for 1
    compact sized calibration
    gas cylinder.
    54-38-01 Calibration/sample draw
    adapter.
    54-38-09 Calibration adapter. Includes
    FEP lined tubing for reactive
    gases (NH3, Cl2, HCN and
    NO2).
    54-38-11 Replacement 10-Pack
    ToxiTube Dosimeter Tubes.
    54-28-01 Carbon Monoxide (CO)
    (35 and 100 ppm)
    54-28-01-C Carbon Monoxide (CO)
    (25 and 100 ppm)
    54-28-02 Hydrogen Sulfide (H2S)
    (10 and 20 ppm)
    10-384 Bump test adapter for
    Mighty-Tox
    54-48-300 LEL/O2            
    54-48-301 LEL/O2/CO            
    54-48-302 LEL/O2/H2S            
    54-48-314 LEL/O2/Duo-Tox (CO/H2S)            
    54-49-80 LEL Combustible Gas 0 – 100% LEL 1% LEL
    54-49-90 O2 Oxygen 0 – 30%/Vol. 0.1%
    54-49-01 CO Carbon Monoxide 0 – 1000 PPM 1 PPM
    54-49-02 H2S Hydrogen Sulfide 0 – 200 PPM 1 PPM
    54-49-14 Duo-Tox Dual Channel CO/H2S CO: 0 – 1000 PPM 1 PPM
    (Provides Substance specific H2S: 0 – 200 PPM 1 PPM
    readouts for CO and H2S)
    54-49-200 MultiPro sensor exchange set. O2, LEL, Duo-Tox  
    54-49-201 MultiPro sensor exchange set. O2, LEL, CO  
    54-49-202 MultiPro sensor exchange set. O2, LEL, H2S  
    54-49-102 Continuous sample pump for
    MultiPro. Includes 10  of sample
    tubing and sample probe
    assembly.
    54-49-104 Sample draw/calibration
    adapter.
    54-49-105 Sample draw kit. Includes
    adapter, squeeze bulb, 10  of
    tubing and sample probe
    assembly.
    54-05-A0403 Sample probe assembly. Does
    not include tubing, squeeze
    bulb, or sample draw adapter.
    54-05-A0405 Sample probe assembly with
    11.5-inch stainless-steel probe
    tube. Does not include tubing,
    squeeze bulb, or sample draw /
    calibration adapter.
    54-49-103-1 Slip-in fast charger (110 VAC)
    for MultiPro. Includes “wallcube”
    supply.
    54-49-103-12 Slip-in fast charger (12 VDC)
    for MultiPro. Includes “cigarette
    lighter” style adapter and vehicle
    mounting hardware.
    54-49-106 MultiPro Alkaline battery pack.
    54-49-107 MultiPro Li-Ion rechargeable
    battery pack.
    54-26-0603 MultiPro BioTrak Software Kit.
    Includes BioTrak software and
    manual.
    54-26-0605S Infrared communication device
    (Serial – IrDA). Requires one
    available PC serial port.
    54-26-0605U Infrared communication device
    (USB – IrDA). Requires one
    USB port.
    54-49-110 MultiPro datalogger upgrade.
    Field upgradeable.
    54-40-30000 LEL/O2          
    54-40-30100 LEL/O2/CO          
    54-40-30200 LEL/O2/H2S          
    54-40-30102 LEL/O2/CO/H2S          
    54-42-80 LEL Combustible Gas 0 – 100% LEL 1% LEL
    54-42-90 O2 Oxygen 0 – 30%/Vol. 0.1%
    54-42-01 CO Carbon Monoxide 0 – 1000 PPM 1 PPM
    54-42-02 H2S Hydrogen Sulfide 0 – 200 PPM 1 PPM
    54-42-101 MultiVision Exchange set of 4 sensors.
    O2, LEL, CO and H2S  
    54-41-004B MultiVision Rubber Boot.
    Black.
    54-41-004R MultiVision Rubber Boot.
    Red.
    54-41-004Y MultiVision Rubber Boot.
    Yellow.
    54-41-007 MultiVision Manual Sample
    draw kit. Includes adapter,
    squeeze bulb, 10  of tubing.
    54-41-008 MultiVision BioTrak Download
    software. Requires MultiVision
    datalogging option be installed.
    Computer must support
    infrared communication (IrDA)
    to download.
    54-26-0605S Infrared communication device
    (Serial – IrDA) – Requires one
    available PC serial port.
    54-26-0605U Infrared communication device
    (USB – IrDA) – Requires one
    available USB port.
    54-41-001 MultiVision Calibration
    Adapter.
    54-41-005 MultiVision Remote Sampling
    Adapter (Manual sample draw).
    54-41-003 MultiVision Remote Sampling
    Adapter (Internal pump).
    Includes pump activation magnet.
    Requires internal pump to
    be installed in MultiVision.
    54-41-006 MultiVision Internal Pump
    Upgrade. Must be returned to
    Biosystems service department.
    This part number includes
    labor charges for upgrade.
    Does not include freight.
    54-41-007 MultiVision Manual sample
    draw kit. Includes adapter,
    squeeze bulb, 10  of tubing and
    sample probe assembly.
    54-05-A0403 Sample probe assembly. Does
    not include tubing, squeeze
    bulb, or sample draw adapter.
    54-05-A0405 Sample probe assembly with
    11.5-inch stainless-steel probe
    tube. Does not include tubing,
    squeeze bulb, or sample draw /
    calibration adapter.
    54-41-002 MultiVision Slip-in fast charger
    (110 VAC). Includes “wall cube”
    supply.
    54-41-010 MultiVision Slip-in fast charger
    (12 VDC). Includes “cigarette
    lighter” style adapter, and vehicle
    mounting hardware.
    54-41-011 MultiVision Five instrument
    110 VAC slip-in multi-charger.
    Includes power supply.
    35-0488 MultiVision Alkaline Battery
    Pack.
    35-0489 MultiVision NiMH Battery
    Pack.
    54-41-016 MultiVision PC programming
    kit. Used for instrument configuration
    only. Includes software
    and serial interface cable.
    54-41-014 MultiVision Datalogger and
    infrared communication (IrDA)
    upgrade. Must be returned to
    Biosystems service department.
    Includes labor charges for
    upgrade. Does not include
    freight.
    54-41-008 MultiVision BioTrak Download
    software. Requires MultiVision
    datalogging option be installed.
    Computer must support
    infrared communication (IrDA)
    to download.
    54-26-0605S Infrared communication device
    (Serial – IrDA) – Requires one
    available PC serial port.
    54-26-0605U Infrared communication device
    (USB – IrDA) – Requires one
    available USB port.
    13-230 MultiVision Reference Manual.
    13-232 MultiVision Quick Reference
    Card.
    22-165 MultiVision training video.
    22-166 MultiVision training CD-ROM.
    54-41-004B MultiVision Rubber Boot.
    Black.
    54-41-004R MultiVision Rubber Boot.
    Red.
    54-41-004Y MultiVision Rubber Boot.
    Yellow.
    42-010 Shoulder Strap.
    54-41-012 MultiVision Case for Value
    Pack. Foam-lined case, with
    room for 1 compact sized calibration
    gas cylinder.
    35-0259 MultiVision Case for Confined
    Space Kit. Foam-lined, waterproof
    Pelican   style case with
    room for one standard sized
    calibration gas cylinder.
    54-41-013 MultiVision Calibration kit.
    Includes foam-lined carrying
    case with room for up to three
    cylinders of calibration gas. Kit
    contains 12-023 regulator and
    other fittings. Kit does not
    include gas.
    54-41-V9045 MultiVision Value Pack “Makeup”
    Kit. Includes Value Pack
    case with 54-9045E calibration
    gas and 12-022 economy regulator.
    For use with O2/LEL and
    O2/LEL/CO configurations.
    54-41-V9047 MultiVision Value Pack “Makeup”
    Kit. Includes Value Pack
    case with 54-9047E calibration
    gas and 12-023 regulator.
    For use with O2/LEL/H2S
    configurations.
    54-41-V9049 MultiVision Value Pack “Makeup”
    Kit. Includes Value Pack
    case with 54-9049E calibration
    gas and 12-023 regulator. For
    use with O2/LEL/CO/H2S
    configurations.
    54-41-001 MultiVision Calibration
    Adapter.
    54-23-000 No Sensors Installed    
    54-23-300 LEL/O2          
    54-23-301 LEL/O2/CO          
    54-23-305 LEL/O2/CO+          
    54-23-319 LEL/O2/CO-H          
    54-23-302 LEL/O2/H2S          
    54-23-314 LEL/O2/Duo-Tox (CO/H2S)          
    54-23-303 LEL/O2/SO2 (0.0-25/0.1 ppm Incr.)        
    54-23-321 LEL/O2/NH3        
    54-23-308 LEL/O2/Cl2 (non-specific)        
    54-23-318 LEL/O2/Cl2 (specific)        
    54-23-312 LEL/O2        
    54-23-320 LEL/O2    
    54-23-309 LEL/O2/NO2        
    54-23-310 LEL/O2/HCN        
    54-23-313 LEL/O2/PH3        
    54-25-80 LEL Combustible Gas 0 – 100% LEL 1% LEL
    54-25-90 O2 Oxygen 0 – 30%/Vol. 0.1%
    54-25-01 CO Carbon Monoxide 0 – 1000 PPM 1 PPM
    54-25-05 CO+ CO Plus dual purpose CO/H2S CO: 0 – 1000 PPM 1 PPM
    (provides a non-specific H2S: 0 – 200 PPM 1 PPM
    readout for CO and H2S)
    54-25-19 CO-H CO Minus, reduced sensitivity 0 – 1000 PPM 1 PPM
    to H2
    54-25-02 H2S Hydrogen Sulfide 0 – 200 PPM 1 PPM
    54-25-14 Duo-Tox Dual Channel CO/H2S CO: 0 – 1000 PPM 1 PPM
    (provides Substance specific H2S: 0 – 200 PPM 1 PPM
    readouts for CO and H2S)
    54-25-03 SO2 Sulfur Dioxide 0 – 25 PPM 0.1 PPM
    54-25-15 SO2-Ext. Sulfur Dioxide extended range 0 – 100 PPM 1 PPM
    54-25-04 NH3 Ammonia 0 – 50 PPM 1 PPM
    (for software versions
    prior to 2.0)
    54-25-21 NH3 Ammonia 0 – 100 PPM 1 PPM
    54-25-08  Cl2 Chlorine (non-specific) 0 – 50 PPM 0.1 PPM
    54-25-18  Cl2 Chlorine (specific) 0 – 50 PPM 0.1 PPM
    54-25-09 NO2 Nitrogen Dioxide 0 – 50 PPM 0.1 PPM
    54-25-10 HCN Hydrogen Cyanide 0 – 100 PPM 0.2 PPM
    54-25-13 PH3 Phosphine 0 – 20 PPM 0.1 PPM
    54-26-0101 Continuous sample pump for
    PhD Lite. Includes 10  of
    sample tubing and sample
    probe assembly.
    54-26-0101-C Continuous sample pump for
    PhD Lite – Configured for reactive
    gas detection, such as Cl2.
    Includes 10  of inert sample
    tubing and sample probe
    assembly.
    54-26-0302 Leather holster. For PhD Lite
    without pump.
    54-26-0306 Leather holster. For PhD Lite
    with pump attached.
    54-26-0603 PhD Lite BioTrak Software Kit.
    Includes BioTrak software and
    manual.
    54-26-0605S Infrared communication device
    (Serial – IrDA) – Requires one
    available PC serial port.
    54-26-0605U Infrared communication device
    (USB – IrDA) – Requires one
    available USB port.
    54-27-0802 TouchID   programming kit.
    Includes software, programming
    wand, serial connector,
    10 TouchID   buttons, 10 key
    chain/wall mounts for buttons
    and 10 TouchID   badges.
    54-26-0101 Continuous sample pump for
    PhD Lite. Includes 10  of sample
    tubing and sample probe
    assembly.
    54-26-0101-C Continuous sample pump for
    PhD Lite – Configured for reactive
    gas detection, such as Cl2.
    Includes 10’ of inert sample
    tubing and sample probe
    assembly.
    35-0344 Tubing kit for reactive gas
    detection (Cl2). Includes 10  of
    tubing plus adapters.
    54-26-0401 Sample draw kit. Includes
    adapter, squeeze bulb, 10  of
    tubing and sample probe
    assembly. Not for use with Cl2.
    54-05-A0403 Sample probe assembly. Does
    not include tubing, squeeze
    bulb, or sample draw adapter.
    54-26-0301 Sample draw/calibration
    adapter.
    54-05-A0405 Sample probe assembly with
    11.5-inch stainless-steel probe
    tube. Does not include tubing,
    squeeze bulb, or sample draw /
    calibration adapter.
    54-26-0201 Slip-in fast charger (110 VAC)
    for PhD Lite. Includes “wall
    cube” supply.
    54-26-0202 Slip-in fast charger (12 VDC)
    for PhD Lite. Includes “cigarette
    lighter” style adapter, and vehicle
    mounting hardware.
    54-26-0204 Five instrument 110 VAC slipin
    multi-charger for PhD Lite.
    Includes power supply.
    54-26-0601   Datalogger upgrade for PhD
    Lite without “Black-Box”
    recorder. (Instrument disassembly
    required.) If your non-datalogging
    PhD Lite shows the
    time and date during startup, it
    does include a “Black-Box”
    recorder.
    54-26-0606   Datalogger upgrade for PhD
    Lite with “Black-Box” recorder.
    54-26-0603 PhD Lite BioTrak Software Kit.
    Includes BioTrak software and
    manual.
    54-26-0605S Infrared communication device
    (Serial – IrDA) – Requires one
    available PC serial port.
    54-26-0605U Infrared communication device
    (USB – IrDA) – Requires one
    available USB port.
    54-27-0802 TouchID   programming kit.
    Includes software, programming
    wand, serial connector, 10
    TouchID   buttons, 10 key
    chain/wall mounts for buttons
    and 10 TouchID   badges.
    54-27-0805 10 TouchID   buttons.
    54-27-0807 10 TouchID   key ring/wall
    mounts. Does not include
    TouchID   buttons.
    54-27-0810 10 TouchID   badges. Does not
    include TouchID   buttons.
    13-088 PhD Lite Reference Manual.
    13-089 PhD Lite Quick Reference Card.
    22-125 PhD Lite training video.
    22-132 PhD Lite interactive training
    CD-ROM.
    54-26-0302 Leather holster. For PhD Lite
    without pump.
    54-26-0306 Leather holster. For PhD Lite
    with pump attached.
    42-011 Wrist strap.
    42-010 Shoulder Strap.
    54-26-0404 Case for Value Pack. Foam-lined
    case, with room for 1 compact
    sized calibration gas cylinder.
    35-0259 Case for Confined Space Kit.
    Foam-lined, waterproof
    Pelican   style case with room
    for one standard sized calibration
    gas cylinder.
    54-26-0501 Calibration kit for PhD Lite.
    Includes foam-lined carrying
    case with room for up to three
    cylinders of calibration gas. Kit
    contains 12-023 regulator and
    other fittings. Kit does not
    include gas.
    54-26-V9045 Value Pack “Make-up” Kit.
    Includes Value Pack case with
    54-9045E calibration gas and
    12-022 economy regulator. For
    use with O2/LEL and O2 /
    LEL/CO, CO+, CO-H configurations.
    54-26-V9047 Value Pack “Make-up” Kit.
    Includes Value Pack case with
    54-9047E calibration gas and
    12-023 regulator. For use with
    O2/LEL/H2S configurations.
    54-26-V9049 Value Pack “Make-up” Kit.
    Includes Value Pack case with
    54-9049E calibration gas and
    12-023 regulator. For use with
    O2/LEL/CO/H2S and O2 /
    LEL/Duo-Tox (CO/H2S)
    configurations.
    54-26-0301 Sample draw/calibration
    adapter for PhD Lite.
    54-26-0405 Calibration adapter for use with
    reactive gases (NH3, Cl2, HCN,
    54-24-00000 No Sensors Installed    
    54-24-30000 LEL/O2          
    54-24-30100 LEL/O2/CO          
    54-24-30500 LEL/O2/CO+          
    54-24-31900 LEL/O2/CO-H          
    54-24-30200 LEL/O2/H2S          
    54-24-30102 LEL/O2/CO/H2S          
    54-24-31400 LEL/O2/Duo-Tox (CO/H2S)          
    54-24-30300 LEL/O2/ SO2        
    54-24-30103 LEL/O2/CO/ SO2        
    54-24-30203 LEL/O2/H2S/ SO2        
    54-24-31403 LEL/O2/Duo-Tox (CO/H2S)/SO2        
    54-24-31421 LEL/O2/Duo-Tox /NH3        
    54-24-31408 LEL/O2/Duo-Tox /Cl2 (non-specific)        
    54-24-31409 LEL/O2/Duo-Tox /NO2        
    54-24-31410 LEL/O2/Duo-Tox /HCN        
    54-24-31412 LEL/O2/Duo-Tox        
    54-24-31413 LEL/O2/Duo-Tox /PH3        
    54-24-31415 LEL/O2/Duo-Tox/SO2 – Ext.        
    54-24-31418 LEL/O2/Duo-Tox /Cl2 (specific)        
    54-24-31420   LEL/O2/Duo-Tox    
    54-24-30121 LEL/O2/CO/NH3        
    54-24-30108 LEL/O2/CO/Cl2 (non-specific)        
    54-24-30109 LEL/O2/CO/NO2        
    54-24-30110 LEL/O2/CO/HCN        
    54-24-30112 LEL/O2/CO        
    54-24-30113 LEL/O2/CO/PH3        
    54-24-30115 LEL/O2/CO/ SO2 – Ext.        
    54-24-30118 LEL/O2/CO/Cl2 (specific)        
    54-24-30120   LEL/O2/CO    
    54-24-31921 LEL/O2/CO-H/NH3        
    54-24-31920   LEL/O2/CO-H    
    54-24-31421 LEL/O2/DuoTox/NH3        
    54-24-31408 LEL/O2/DuoTox/Cl2 (non specific)        
    54-24-31409 LEL/O2/DuoTox/NO2        
    54-24-31410 LEL/O2/DuoTox/HCN        
    54-24-31412 LEL/O2/DuoTox        
    54-24-31413 LEL/O2/DuoTox/PH3        
    54-24-31415 LEL/O2/DuoTox/SO2-Ext.        
    54-24-31418 LEL/O2/DuoTox/Cl2 (specific)        
    54-24-31420   LEL/O2/DuoTox    
    54-24-30121 LEL/O2/CO/NH3        
    54-24-30108 LEL/O2/CO/Cl2 (non specific)        
    54-24-30109 LEL/O2/CO/NO2        
    54-24-30110 LEL/O2/CO/HCN        
    54-24-30112 LEL/O2/CO        
    54-24-30113 LEL/O2/CO/PH3        
    54-24-30115 LEL/O2/CO/SO2-Ext.        
    54-24-30118 LEL/O2/CO/Cl2 (specific)        
    54-24-30120   LEL/O2/CO    
    54-24-31921 LEL/O2/CO-H/NH3        
    54-24-31920   LEL/O2/CO-H    
    54-24-30521 LEL/O2/CO+/NH3        
    54-24-30508 LEL/O2/CO+/Cl2 (non specific)        
    54-24-30509 LEL/O2/CO+/NO2        
    54-24-30510 LEL/O2/CO+/HCN        
    54-24-30512 LEL/O2/CO+        
    54-24-30513 LEL/O2/CO+/PH3        
    54-24-30515 LEL/O2/CO+/SO2-Ext.        
    54-24-30518 LEL/O2/CO+/Cl2 (specific)        
    54-24-30520   LEL/O2/CO+    
    54-24-30221 LEL/O2/H2S/NH3        
    54-24-30208 LEL/O2/H2S/Cl2 (non specific)        
    54-24-30209 LEL/O2/H2S/NO2        
    54-24-30210 LEL/O2/H2S/HCN        
    54-24-30212 LEL/O2/H2S        
    54-24-30213 LEL/O2/H2S/PH3        
    54-24-30215 LEL/O2/H2S/SO2-Ext.        
    54-24-30218 LEL/O2/H2S/Cl2 (specific)        
    54-24-30219 LEL/O2/H2S/CO-H        
    54-24-30220   LEL/O2/H2S    
    54-24-30321 LEL/O2/SO2/NH3        
    54-24-30305 LEL/O2/SO2/CO+        
    54-24-30308 LEL/O2/SO2/Cl2 (non specific)        
    54-24-30309 LEL/O2/SO2/NO2        
    54-24-30310 LEL/O2/SO2/HCN        
    54-24-30312 LEL/O2/SO2        
    54-24-30313 LEL/O2/SO2/PH3        
    54-24-30318 LEL/O2/SO2/Cl2 (specific)        
    54-24-30319 LEL/O2/SO2/CO-H        
    54-24-30320   LEL/O2/SO2    
    54-24-30321 LEL/O2/SO2/NH3        
    54-24-30800 LEL/O2/Cl2 (non specific)        
    54-24-30821 LEL/O2/Cl2 (non specific)/NH3        
    54-24-30809 LEL/O2/Cl2 (non specific)/NO2        
    54-24-30810 LEL/O2/Cl2 (non specific)/HCN        
    54-24-30813 LEL/O2/Cl2 (non specific)/PH3        
    54-24-30815 LEL/O2/Cl2 (non specific)/SO2-Ext.        
    54-24-30819 LEL/O2/Cl2 (non specific)/CO-H        
    54-24-30900 LEL/O2/NO2        
    54-24-30921 LEL/O2/NO2/NH3        
    54-24-30910 LEL/O2/NO2/HCN        
    54-24-30912 LEL/O2/NO2        
    54-24-30913 LEL/O2/NO2/PH3        
    54-24-30915 LEL/O2/NO2/SO2-Ext.        
    54-24-30918 LEL/O2/NO2/Cl2 (specific)        
    54-24-30919 LEL/O2/NO2/CO-H        
    54-24-30920   LEL/O2/NO2    
    54-24-31000 LEL/O2/HCN        
    54-24-31012 LEL/O2/HCN        
    54-24-31015 LEL/O2/HCN/SO2-Ext.        
    54-24-31018 LEL/O2/HCN/Cl2 (specific)        
    54-24-31019 LEL/O2/HCN/CO-H        
    54-24-31020   LEL/O2/HCN    
    54-24-31221 LEL/O2/NH3        
    54-24-31200 LEL/O2        
    54-24-31213 LEL/O2/PH3        
    54-24-31215 LEL/O2/SO2-Ext.        
    54-24-31219 LEL/O2/CO-H        
    54-24-31300 LEL/O2/PH3        
    54-24-31315 LEL/O2/PH3/SO2-Ext.        
    54-24-31318 LEL/O2/PH3/Cl2 (specific)        
    54-24-31319 LEL/O2/PH3/CO-H        
    54-24-31320   LEL/O2/PH3    
    54-24-31500 LEL/O2/SO2-Ext.        
    54-24-31521 LEL/O2/SO2-Ext./NH3        
    54-24-31518 LEL/O2/SO2-Ext./Cl2 (specific)        
    54-24-31519 LEL/O2/SO2-Ext./CO-H        
    54-24-31520   LEL/O2/SO2-Ext.    
    54-24-31800 LEL/O2/Cl2 (specific)        
    54-24-31821 LEL/O2/Cl2 (specific)/NH3        
    54-24-31819 LEL/O2/Cl2 (specific)/CO-H        
    54-24-31820   LEL/O2/Cl2 (specific)    
    54-24-32000   LEL/O2    
    54-24-32021   LEL/O2/NH3    
    54-24-32100 LEL/O2/NH3        
    54-27-0205 Slip-in fast charger (110 VAC)
    for PhD5. Includes “wall cube”
    power supply.
    54-27-0201 Slip-in fast charger/data dock
    (110 VAC) for PhD5. Includes
    “wall cube” power supply.
    54-27-0202 Slip-in fast charger (12 VDC)
    for PhD5. Includes 12 VDC
    “cigarette lighter” style adapter,
    and vehicle mounting hardware.
    54-27-0204 Five instrument 110 VAC slipin
    multi-charger for PhD5.
    Includes power supply.
    35-0219 Alkaline battery pack for PhD5.
    35-0214 NiCad battery pack for PhD5.
    54-27-0601   Datalogger upgrade for PhD5
    without “Black-Box” recorder.
    (Requires instrument disassembly.)
    (If your non-datalogging
    PhD5 shows the time and date
    during startup, it does include a
    “Black-Box” recorder.)
    54-27-0607   Datalogger upgrade for PhD5
    with “Black-Box” recorder.
    (If your non-datalogging PhD5
    shows the time and date during
    startup, it does include a
    “Black-Box” recorder.)
    54-27-0603 BioTrak Software Kit. Includes
    computer cable, software and
    manual.
    54-27-0605 PhD5 Datalink Kit. Includes
    download cradle, BioTrak
    software, computer cable and
    manual.
    54-27-0802 TouchID   programming kit.
    Includes software, programming
    wand, serial connector,
    10 buttons, 10 key chain/wall
    mounts for TouchID   buttons
    and 10 TouchID   badges.
    54-27-0805 10 TouchID   buttons.
    54-27-0807 10 TouchID   key ring/wall
    mounts. Does not include
    TouchID   buttons.
    54-27-0810 10 TouchID   badges. Does not
    include TouchID   buttons.
    54-25-80A LEL Combustible gas 0 – 100% LEL 1% LEL
    54-04-90 O2 Oxygen 0 – 30%/Vol. 0.1%
    54-25-01 CO Carbon Monoxide 0 – 1000 PPM 1 PPM
    54-25-05 CO+ CO Plus dual purpose CO/H2S CO: 0 – 1000 PPM 1 PPM
    (provides a non-specific H2S: 0 – 200 PPM 1 PPM
    readout for CO and H2S)
    54-25-19 CO-H CO Minus, reduced sensitivity 0 – 1000 PPM 1 PPM
    to H2
    54-25-02 H2S Hydrogen Sulfide 0 – 200 PPM 1 PPM
    54-25-14 Duo-Tox Dual Channel CO/H2S CO: 0 – 1000 PPM 1 PPM
    (provides substance specific H2S: 0 – 200 PPM 1 PPM
    readouts for CO and H2S)
    54-25-03 SO2 Sulfur Dioxide 0 – 25 PPM 0.1 PPM
    54-25-15 SO2-Ext. Sulfur Dioxide extended range 0 – 100 PPM 1 PPM
    54-25-04 NH3 Ammonia 0 – 50 PPM 1 PPM
    (for software versions
    prior to 2.0)
    54-25-21 NH3 Ammonia 0 – 100 PPM 1 PPM
    54-25-08  Cl2 Chlorine (non-specific) 0 – 50 PPM 0.1 PPM
    54-25-18  Cl2 Chlorine (specific) 0 – 50 PPM 0.1 PPM
    54-25-09 NO2 Nitrogen Dioxide 0 – 50 PPM 0.1 PPM
    54-25-10 HCN Hydrogen Cyanide 0 – 100 PPM 0.2 PPM
    54-25-13 PH3 Phosphine 0 – 20 PPM 0.1 PPM
    13-092 PhD5 Reference Manual.
    13-093 PhD5 Quick Reference Card.
    22-130 PhD5 training video.
    22-131 PhD5 interactive training
    CD-ROM.
    42-005 Shoulder strap for PhD5.
    45-016 Leather weather cover for
    PhD5.
    56-282 Leather weather cover for
    PhD5 with TouchID  .
    PhD5 Calibration Materials and
    Carrying Cases
    PART NO. DESCRIPTION
    54-27-0401 Case for Value Pack. Foamlined
    case, with room for
    1 compact sized calibration
    gas cylinder.
    35-0002 Case for Confined Space Kit.
    Foam-lined, waterproof
    Pelican   style case with room
    for one standard sized
    calibration gas cylinder.
    54-27-0501 Calibration kit for PhD5.
    Includes foam-lined carrying
    case with room for up to three
    cylinders of calibration gas.
    Kit contains 12-023 regulator
    and other fittings. Kit does not
    include gas.
    54-27-V9045 Value Pack “Make-up” Kit.
    Includes Value Pack case with
    54-9045E calibration gas and
    12-022 regulator. For use with
    O2/LEL; O2/LEL/CO and
    O2/LEL/CO+ configurations.
    54-27-V9047 Value Pack “Make-up” Kit.
    Includes Value Pack case with
    54-9047E calibration gas and
    12-023 regulator. For use with
    O2/LEL/H2S configurations.
    54-27-V9049 Value Pack “Make-up” Kit.
    Includes Value Pack case with
    54-9049E calibration gas and
    12-023 regulator. For use with;
    O2/LEL/CO/H2S and O2 /
    LEL/Duo-Tox (CO/H2S)
    configurations.
    10-263 Sample draw/calibration
    adapter for PhD5.
    54-05-A0409 Calibration adapter for use
    with reactive gases (NH3,
    Cl2, HCN, NO2).
    54-34-00000 No Sensors Installed    
    54-34-30000 LEL/O2    
    54-34-30100 LEL/O2/CO    
    54-34-31900 LEL/O2/CO-H    
    54-34-30200 LEL/O2/H2S    
    54-34-31400 LEL/O2/Duo-Tox (CO/H2S)    
    54-34-30102 LEL/O2/CO/H2S    
    54-34-30300 LEL/O2/SO2    
    54-34-30103 LEL/O2/CO/SO2    
    54-34-30203 LEL/O2/H2S/SO2    
    54-34-31403 LEL/O2/Duo-Tox (CO/H2S)/SO2    
    54-34-31500 LEL/O2/SO2 Ext.    
    54-34-32100 LEL/O2/NH3    
    54-34-30800 LEL/O2/Cl2 (non-specific)    
    54-34-31800 LEL/O2/Cl2 (specific)    
    54-34-31200 LEL/O2    
    54-34-32000 LEL/O2    
    54-34-30900 LEL/O2/NO2    
    54-34-50000 HC-PPM LEL/O2    
    54-34-50100 HC-PPM LEL/O2/CO    
    54-34-51400 HC-PPM LEL/O2/Duo-Tox (CO/H2S)    
    54-34-50102 HC-PPM LEL/O2/CO/H2S    
    54-35-00000 No Sensors Installed    
    54-35-30000 LEL/O2    
    54-35-30100 LEL/O2/CO    
    54-35-31900 LEL/O2/CO-H    
    54-35-30200 LEL/O2/H2S    
    54-35-31400 LEL/O2/Duo-Tox (CO/H2S)    
    54-35-30102 LEL/O2/CO/H2S    
    54-35-30300 LEL/O2/SO2    
    54-35-30103 LEL/O2/CO/SO2    
    54-35-30203 LEL/O2/H2S/SO2    
    54-35-31403 LEL/O2/Duo-Tox (CO/H2S)/SO2    
    54-35-31500 LEL/O2/SO2 Ext.    
    54-35-32100 LEL/O2/NH3    
    54-35-30800 LEL/O2/Cl2 (non-specific)    
    54-35-31800 LEL/O2/Cl2 (specific)    
    54-35-31200 LEL/O2    
    54-35-32000 LEL/O2    
    54-35-30900 LEL/O2/NO2    
    54-35-50000   HC-PPM LEL/O2    
    54-35-50100   HC-PPM LEL/O2/CO    
    54-35-51400   HC-PPM LEL/O2/Duo-Tox (CO/H2S)    
    54-35-50102   HC-PPM LEL/O2/CO/H2S    
    54-25-80 LEL Combustible Gas 0 – 100% LEL 1% LEL
    54-25-70 LEL Combustible Gas 0 – 100% LEL 1% LEL
    54-25-71 HC-PPM LEL Combustible Gas 0 – 100% LEL see note  
    54-25-90 O2 Oxygen 0 – 30%/Vol. 0.1%
    54-25-01 CO Carbon Monoxide 0 – 1000 PPM 1 PPM
    54-25-05 CO+ CO Plus dual purpose CO: 0 – 1000 PPM 1 PPM
    CO/H2S (provides a H2S: 0 – 200 PPM 1 PPM
    non-specific readout
    for CO and H2S)
    54-25-19 CO-H CO Minus, reduced 0 – 1000 PPM 1 PPM
    sensitivity to H2
    54-25-02 H2S Hydrogen Sulfide 0 – 200 PPM 1 PPM
    54-25-14 Duo-Tox Dual Channel CO/H2S CO: 0 – 1000 PPM 1 PPM
    (provides Substance H2S: 0 – 200 PPM 1 PPM
    specific readouts
    for CO and H2S)
    54-25-03 SO2 Sulfur Dioxide 0 – 25 PPM 0.1 PPM
    54-25-15 SO2-Ext. Sulfur Dioxide 0 – 100 PPM 1 PPM
    extended range
    54-25-21 NH3 Ammonia 0 – 100 PPM 1 PPM
    54-25-08  Cl2 Chlorine 0 – 50 PPM 0.1 PPM
    (non-specific)
    54-25-18  Cl2 Chlorine 0 – 50 PPM 0.1 PPM
    (specific)
    54-25-09 NO2 Nitrogen Dioxide 0 – 50 PPM 0.1 PPM
    54-25-13 PH3 Phosphine 0 – 20 PPM 0.1 PPM
    54-25-06 NO Nitric Oxide 0 – 350 PPM 1 PPM
    35-0379 Cannonball3 motorized sample
    draw pump module.
    35-0378 Cannonball3 motorized sample
    draw pump module for dual
    pump version (2 pumps). The
    Cannonball3 must be configured
    for dual pump.
    35-0376 Cannonball3 Alkaline battery
    pack (“D”-Cell batteries not
    included).
    35-0377 Cannonball3 NiMH battery
    pack.
    54-26-0603 Cannonball3 BioTrak Software
    Kit. Includes BioTrak software
    and manual.
    54-26-0605S Infrared communication device
    (Serial – IrDA) – Requires one
    available PC serial port.
    54-26-0605U Infrared communication device
    (USB – IrDA) – Requires one
    available USB port.
    54-27-0802 TouchID   programming
    kit. Includes software,
    programming wand, serial
    connector, 10 buttons,
    10 key chain/wall mounts
    for TouchID   buttons and
    10 TouchID   badges.
    35-0379 Cannonball3 motorized sample
    draw pump.
    35-0378 Cannonball3 motorized sample
    draw pumps for dual pump version.
    The Cannonball3 must be
    configured for dual pump.
    54-36-03 Cannonball3 Sample probe with
    plastic extension and male
    quick disconnect.
    54-36-04 Cannonball3 Sample probe with
    stainless steel extension and
    male quick disconnect.
    54-36-05 Cannonball3 Sample probe with
    plastic extension and threaded
    for quick disconnect fitting.
    54-36-06 Cannonball3 Sample probe with
    stainless steel extension and
    threaded for quick disconnect
    fitting.
    54-36-07 Cannonball3 Sample probe
    male quick disconnect.
    54-36-08-010 Cannonball3 Extension hose, 10
    feet with male and female quick
    disconnect.
    54-36-08-025 Cannonball3 Extension hose, 25
    feet with male and female quick
    disconnect.
    54-36-08-050 Cannonball3 Extension hose, 50
    feet with male and female quick
    disconnect.
    54-36-08-100 Cannonball3 Extension hose,
    100 feet with male and female
    quick disconnect.
    54-36-09 Cannonball3 set of male and
    female quick disconnects.
    54-36-10 Cannonball3 Snap-on fast
    charger (110VAC).
    54-36-11 Cannonball3 Snap-on fast
    charger (12VDC).
    35-0376 Cannonball3 Alkaline battery
    pack (batteries not included).
    35-0377 Cannonball3 NiMH battery
    pack.
    54-36-13   Cannonball3 Datalogger
    upgrade.
    54-26-0603 Cannonball3 BioTrak Software
    Kit. Includes BioTrak software
    and manual.
    54-26-0605S Infrared communication device
    (Serial – IrDA) - Requires one
    available PC serial port.
    54-26-0605U Infrared communication device
    (USB – IrDA) - Requires one
    available USB port.
    54-27-0802 TouchID   programming kit.
    Includes software, programming
    wand, serial connector, 10
    buttons, 10 key chain/wall
    mounts for TouchID   buttons
    and 10 TouchID   badges.
    54-27-0805 10 TouchID   buttons.
    54-27-0807 10 TouchID   key ring/wall
    mounts. Does not include
    TouchID   buttons.
    54-27-0810 10 TouchID   badges. Does not
    13-173 Cannonball3 Reference Manual.
    31-292 Cannonball3 Quick Reference
    Label.
    22-143 Cannonball3 Training Video.
    42-002 Cannonball3 Shoulder strap.
    54-36-20 Cannonball3 Gasket service kit.
    Includes 6 filter gaskets, 2
    pump gasket, 2 battery gasket
    and lubricant for gaskets.
    54-36-17 Internal filter kit for
    Cannonball3. (10 ea. particulate
    and 5 ea. hydrophobic).
    54-36-14 Cannonball3 Calibration kit.
    Includes foam-lined carrying
    case with room for up to three
    cylinders of calibration gas. Kit
    contains 12-023 regulator and
    other fittings. Kit does not
    include gas.
    35-0453 Cannonball3 Waterproof
    Pelican   style carrying case
    with room for one Cannonball3
    and one cylinder of calibration
    gas.
    54-36-15 Cannonball3 Calibration tube
    with male quick disconnect.
    54-36-18 Cannonball3 Calibration balloon
    (not for use with Cl2).
    54-36-16 Cannonball3 Inert calibration
    tube (for reactive gases) with
    male quick disconnect.
    54-46-9000 IQ Express Docking Station
    for O2, CO, H2S, SO2 with
    Software, Installation Disks,
    and Manuals.
    54-46-9000N Network Compatible.
    54-46-9100 Enhanced IQ Express Docking
    Station for O2, CO, H2S, SO2,
    Cl2, NO2, NH3, HCN, PH3
    with Software, Installation
    Disks, and Manuals.
    54-46-9100N Network Compatible.
    54-46-8000 Mounting Bracket.
    54-46-8001 Powered Mounting Bracket.
    54-43-0x0yz IQ Controller with IQ controller
    software, installation
    disks and manuals. Please
    complete part number using
    the IQ Controller options
    matrix below. Note some
    options affect the price of the
    controller.
    54-43-201 IQ Database Manager software.
    Note this software is
    included with the IQ
    Controller above.
    54-43-1401   IQ Dock for MultiVision.
    54-43-1231 IQ Dock for PhD Lite.
    54-43-1241 IQ Dock for PhD5.
    54-43-1341 IQ Dock for Cannonball3.
    54-43-1481 IQ Dock for MultiPro.
    54-43-1021 IQ Dock for PhD Ultra.
    54-43-200 IQ DataLink software, installation
    disks and manuals.
    Supports PhD Lite, PhD5,
    PhD Ultra, MultiVision
    (Datalog ging) and Cannonball3.
    Note communication
    hardware is not included.
    54-43-201 IQ Database Manager software.
    Note this software is
    included with the IQ DataLink
    software package above.
    54-43-202 IQ DataLink software with
    serial download cradle, installation
    disks and manuals.
    Same as P/N 54-43-200, but
    also includes PhD5 (PhD
    Ultra) charger and download
    cradle, with serial cable and
    power supply.
    54-43-203 IQ DataLink software with
    IrDA (Serial), installation disks
    and manuals. Same as P/N
    54-43-200, but also includes a
    Serial – IrDA communication
    device and download cradle.
    IrDA communication is
    required for PhD Lite, Multi -
    Vision (datalogging) and
    MultiPro.
    54-43-204 IQ DataLink software with,
    IrDA (USB), installation disks
    and manuals. Same as
    P/N 54-43-200, but also
    includes a Serial – IrDA
    communication device and
    download cradle. IrDA communication
    is required for
    PhD Lite, Multi Vision (datalogging)
    and MultiPro.
    54-9041 Methane 50% LEL 50 ppm 5 years 103 liters
    54-9043   Methane 50% LEL 50 ppm 25 ppm 1 year 58 liters
    54-9042E Propane Equivalent 50% LEL 50 ppm 5 years 103 liters
    54-9045E Propane Equivalent 50% LEL 50 ppm 5 years 34 liters
    54-9044E   Propane Equivalent 50% LEL 50 ppm 25 ppm 1 year 58 liters
    54-9049E   Propane Equivalent 50% LEL 50 ppm 25 ppm 1 year 34 liters
    54-9048E Propane Equivalent 50% LEL 25 ppm 1 year 58 liters
    54-9047E Propane Equivalent 50% LEL 25 ppm 1 year 34 liters
    54-9070E Pentane Equivalent 50% LEL 50 ppm 5 years 103 liters
    54-9046E Pentane Equivalent 50% LEL 50 ppm 25 ppm 1 year 58 liters
    54-9071E Pentane Equivalent 50% LEL 50 ppm 5 years 34 liters
    54-9031 LEL Methane 50% LEL 5 Years 103 liters
    54-9032E LEL Propane Equivalent 50% LEL 5 Years 103 liters
    54-9068E LEL Pentane Equivalent 50% LEL 5 Years 103 liters
    54-9066 LEL Hydrogen (H2) 50% LEL 5 Years 103 liters
    54-9033 CO Carbon Monoxide 50 ppm 5 Years 103 liters
    54-9036 CO Carbon Monoxide 50 ppm 5 Years 34 liters
    54-9067 CO Carbon Monoxide 125 ppm 5 Years 103 liters
    (Mighty-Tox series
    bump test only)
    54-9034 H2S Hydrogen Sulfide 25 ppm 1 Year 58 liters
    54-9057 H2S Hydrogen Sulfide 25 ppm 1 Year 34 liters
    54-9037 SO2 Sulfur Dioxide 10 ppm 1 Year 58 liters
    54-9058 SO2 Sulfur Dioxide 10 ppm 1 Year 34 liters
    54-9051   NH3 Ammonia 50 ppm 1 Year 58 liters
    54-9061   NH3 Ammonia 50 ppm 1 Year 34 liters
    54-9052 Cl2 Chlorine 5 ppm 8 Months 58 liters
    54-9062 Cl2 Chlorine 5 ppm 8 Months 34 liters
    54-9056 NO2 Nitrogen Dioxide 5 ppm 6 Months 58 liters
    54-9059 NO2 Nitrogen Dioxide 5 ppm 6 Months 34 liters
    54-9054 HCN Hydrogen Cyanide 10 ppm 1 Year 58 liters
    54-9053 HCl Hydrogen Chloride 10 ppm 1 Year 58 liters
    54-9065 PH3 Phosphine 5 ppm 6 Months 58 liters
    54-9073 PH3 Phosphine 5 ppm 6 Months 34 liters
    54-9064 H2 Hydrogen 100 ppm 5 Years 103 liters
    54-9035 N2 Nitrogen 99.9% 5 Years 103 liters
    54-9039 O2 Oxygen (Zero Air) 20.9% 5 Years 103 liters
    12-022 Regulator, 1.0 liter per minute
    flow. Only for use with 54-9036
    54-9045E and 54-9071E
    calibration gas cylinders.
    12-023 Regulator, standard service 1.0
    liter per minute flow.
    12-025 Regulator, ammonia service 1.0
    liter per minute flow.
    12-030 Regulator, standard service 1.0
    liter per minute flow with on/off
    knob.
    12-039 Demand flow regulator, standard
    service, 0 – 3 liters per minute
    flow.
    35-0380 AirChek 3000 PSI Regulator. 1.0
    liter per minute regulator with
    CGA346 hand-wheel coupling.
    54-04-80 LEL Combusible Gas    
    54-04-90 O2 Oxygen    
    54-04-01 CO Carbon Monoxide    
    54-04-02 H2S Hydrogen Sulfide    
    54-04-03 SO2 Sulfur Dioxide    
    54-04-04 NH3 Ammonia  
    54-04-05 CO+ Dual purpose CO/H2S    
    (provides a non-specific readout
    for CO and H2S)
    54-04-08 Cl2 Chlorine  
    54-04-09 NO2 Nitrogen Dioxide  
    54-04-10 HCN Hydrogen Cyanide  
    (special version of PhD Ultra required)
    54-04-13 PH3 Phosphine  
    3101 Oxygen sensor for Model 3100.
    3102 Remote Oxygen sensor for Model
    3100R.
    3301 Carbon monoxide sensor, CO for
    Models 3300 and 3300-TP.
    3350 Compressed air sampling kit with
    fixed flow regulator. Rated 10 –
    200 psig. Specify 3/8" Hansen “-
    H” or 3/8" Schraeder “-S” male
    QD fitting when ordering.
    35-179 Air sampling assembly (sensor/
    calibration adapter and tubing).
    35-043 Battery Eliminator (110 VAC).
    35-197 Relay Closure, simply closes a circuit
    upon alarm condition, rated
    at no more than 110 VAC and 1
    amp service. Factory installation
    required, must be specified at
    time of purchase.
    6050 High-intensity remote alarm (115
    dBA @ 12") Includes mounting
    plate, 9V battery, test button, 6  of
    cable Not intrinsically safe; may
    not be used in potentially combustible
    environments.
    55-025 Wall mounting plate for
    3300-TP. Accepts monitor
    mounted bracket.
    54-16-90 O2 Oxygen      
    54-16-80 LEL Combustible  
    54-16-01 CO Carbon Monoxide      
    54-16-02 H2S Hydrogen Sulfide      
    54-16-03 SO2 Sulfur Dioxide      
    54-16-08 Cl2 Chlorine    
    54-16-13 PH3 Phosphine      
    54-16-09 NO2 Nitrogen Dioxide      
    54-15-801-S LEL Combustible
    54-1631 O2 Oxygen
    54-1632 H2S Hydrogen Sulfide
    54-1634 CO Carbon Monoxide
    54-1635 Cl2 Chlorine
    54-1636 SO2 Sulfur Dioxide
    54-1637 NO2 Nitrogen Dioxide
    54-17-A0101 Single integrally mounted
    external strobe for ZoneGuard
    (Red).
    54-17-A0103 Single integrally mounted
    external strobe for ZoneGuard
    (Amber).
    54-17-A0102 Dual integrally mounted
    external strobes for ZoneGuard
    (Red and Amber).
    54-17-A0201 Remote programmable (volume
    adjustable) audible alarm.
    54-17-A0202 Remote high intensity audible
    alarm.
    54-17-A0301 Splash guard for sensors
    installed in explosion proof
    remote housings.
    54-17-A0302 Splash guard for sensors
    installed in standard housings.
    54-17-A0401 Wire, 22 gauge, 6 conductor,
    twisted pair, shielded with
    drain, used to connect Oxygen
    remote detectors with
    ZoneGuard controller, 50'.
    54-17-A0402 Wire, 22 gauge, 4 conductor,
    twisted pair, shielded with
    drain, used to connect toxic
    remote detectors with
    ZoneGuard controller, 50'.
    54-17-A0403 Wire, 18 gauge, 4 conductor,
    twisted pair, shielded with
    drain, used to connect combustible
    remote detectors with
    ZoneGuard controller, 50'.
    54-17-A0310 ZoneGuard airline adapter
    (10-200 psig) with Hanson
    fitting.
    35-0136 Calibration adapter for
    ZoneGuard and Gas Chek
    (Oxygen/standard toxic
    sensors).
    54-17-A0304 Calibration adapter for
    ZoneGuard and Gas Chek
    (LEL sensors).
    10-302 Calibration adapter for
    ZoneGuard and Gas Chek
    (Reactive gas sensors – Cl2).
    54-49-01 CO Sensor  
    54-49-90 O2 Sensor  
    54-9033 Calibration/Test Gas, CO 50 ppm, 103 liters (requires 12-023
    regulator).
    12-023 Regulator for 54-9033.
    54-9036 Calibration/Test Gas, \CO 50 ppm, 34 liters (requires 12-022
    regulator).
    12-022 Regula tor for 54-9036.
    54-51-001 Calibration Kit (includes 54-9033 CO calibration/test gas,
    12-023 regulator and foam lined plastic carrying case).
    54-51-002 Value Calibration Kit (includes 54-9036 CO calibration/test gas,
    12-022 regulator and foam lined plastic carrying case).
    54-51-003 Filter Kit (includes Pre-filter, coalescing filter, charcoal filter,
    and O-rings).
    54-50-002 A= 1 CO
    3 CO and O2
    B= 0 No Options
    1 LED Strobe Light
    2 Locking Stabilizer Legs
    3 Both
    C= 0 No Option
    1 Low Pressure Alarm
    D=N Rechargeable
    A Alkaline  
    E =H Hansen outlet fitting
    S Schraeder outlet fitting
    54-50-331NH Travel Panel 50MP with CO/O2 sensors,LED
    Strobe Light, Locking Stabilize Legs, Low Pressure
    Alarm, Rechargeable battery, and Hansen outlet
    fittings.
    54-50-100NH Hansen Outlet Fittings.
    54-50-100NS Schraeder Outlet Fittings.
    54-05-A0403 Plastic Standard barb fitting.
    54-05-A0405 Stainless Steel Standard barb fitting.
    54-36-03 Plastic Male quick disconnect (QD).
    54-36-04 Stainless Steel Male quick disconnect (QD).
    54-36-05 Plastic Threaded for quick disconnect. Intended as replacement
    where existing QD is reused.
    54-36-06 Stainless Steel Threaded for quick disconnect. Intended as replacement
    where existing QD is reused.
    10-270 Standard probe handle (upper)
    61-047 Hydrophobic filter
    10-268 Filter cup
    10-267 Probe handle (lower)
    10-269 Hex-nut compression fitting
    17-063 O-ring
    05-1153 Male quick disconnect for threaded probe
    10-423 Threaded probe handle (upper)
    61-046 Particulate filter
    17-033 O-ring
    56-173 Compression sleeve
    56-439 Interchangeable probe tube, Plastic
    56-919 Interchangeable probe tube, Steel
    54-05-K0401 Filter replacement kit.
    10 Particulate (61-046).
    3 Hydrophobic (61-047) filters.
    54-05-K0403 Economy filter replacement kit.
    30 Particulate (61-046).
    10 Hydrophobic (61-047) filters.
    54-05-K0402 Economy filter replacement
    pack. 10 Particulate (61-046)
    filters.
    54-05-K0405 Bulk filter replacement pack.
    100 Particulate (61-046) filters.
    54-05-K0404 Bulk filter replacement pack.
    25 Hydrophobic (61-047) filters.
    54-05-K0406 100 Hydrophobic filters.
    54-05-K0407 500 Hydrophobic filters.
    53-001 Polyurethane (fuel resistant)
    tubing 5/16" OD, 3/16" ID.
    35-0344 Tubing kit for reactive gas
    detection (Cl2). Includes 10  of
    tubing plus adapters.
    Internal Filters
    for Motorized Pumps
    PART NO. DESCRIPTION
    54-05-K0101 Internal filter kit for PhD
    pumps. 10 particulate filters.
    54-36-17 Internal filter kit for
    Cannonball3. 10 particulate,
    5 hydrophobic filters.
    35-0408 In-line cartridge filter for
    Cannonball3. 1 particulate
    filter.
    54-20-1117-32 Low & High Pressure
    with Middle Stage
    Transducer, including
    Enhanced Precision
    (EP) Transducer and
    32-Bit PosiChek3
    software
    54-20-1117-32-L PosiChek3 (EP) with
    laptop computer
    package
    54-20-1117-32-D PosiChek3 (EP)
    with desktop
    computer package
    54-20-2117-32 Low & High Pressure
    with Middle Stage
    Transducer, including
    Enhanced Precision
    (EP) Transducer,
    Sound Detection
    System (SDS) and
    32-Bit PosiChek3
    software
    54-20-1117-32-L PosiChek3 (EP & SDS)
    with laptop computer
    package
    Upgrade your existing PosiChek3
    PART NO. DESCRIPTION
    54-21-A12 Enhanced Precision
    (EP) Transducer
    Upgrade
    54-21-A13 Sound Detection
    System (SDS) Upgrade
    (Must have EP)
    54-21-A14 EP and SDS Upgrade

    在线询盘/留言 请仔细填写准确及时的联系到你!

    您的姓名:
    联系手机:
    固话电话:
    联系邮箱:
    所在单位:
    需求数量:
    要求提供:
    咨询内容:
      
    声明以上所展示的信息由会员自行提供,内容的真实性、准确性和合法性由发布会员负责。本网对此不承担任何责任。友情提醒:为规避购买风险,建议您在购买相关产品前务必确认供应商资质及产品质量。
0571-87774297